                                 CERT-Renater

                      Note d'Information No. 2022/VULN272

_____________________________________________________________________

DATE                : 23/08/2022

HARDWARE PLATFORM(S): /

OPERATING SYSTEM(S): Systems running PowerDNS Recursor versions prior
                                 to 4.5.10, 4.6.3, 4.7.2.

=====================================================================
https://docs.powerdns.com/recursor/security-advisories/powerdns-advisory-2022-02.html
_____________________________________________________________________


PowerDNS Security Advisory 2022-02: incomplete exception handling
related to protobuf message generation

     CVE: CVE-2022-37428
     Date: 23th of August 2022.
     Affects: PowerDNS Recursor up to and including 4.5.9, 4.6.2 and
              4.7.1
     Not affected: PowerDNS Recursor 4.5.10, 4.6.3 and 4.7.2
     Severity: Medium
     Impact: Denial of service
     Exploit: This problem can be triggered by a remote attacker with
       access to the recursor if protobuf logging is enabled
     Risk of system compromise: None
     Solution: Upgrade to patched version, disable protobuf logging
       of responses

This issue only affects recursors which have protobuf logging
enabled using the

     protobufServer function with logResponses=true or
     outgoingProtobufServer function with logResponses=true

If either of these functions is used without specifying logResponses,
its value is true. An attacker needs to have access to the recursor,
i.e. the remote IP must be in the access control list. If an
attacker queries a name that leads to an answer with specific
properties, a protobuf message might be generated that causes
an exception. The code does not handle this exception correctly,
causing a denial of service.


=========================================================
+ CERT-RENATER        |    tel : 01-53-94-20-44         +
+ 23/25 Rue Daviel    |    fax : 01-53-94-20-41         +
+ 75013 Paris         |   email:cert@support.renater.fr +
=========================================================